Variable model was not provied - Connection Error #171

Closed ehskha closed 1 year ago

ehskha commented 1 year ago

Hi,

I have a Thermia Diplomat Inverter and I have downloaded and installed all the files here according to the instructions.

When Adding the Integration, I see this error window.

image

Even after entering the IP-address, I get connection error. What am I doing wrong?

nhogblom commented 1 year ago

Change homeassistant language to Swedish and it will work, this should work. No idea if a fix for this is being worked on.

ehskha commented 1 year ago

Thanks. Seems as that solved one part. I still get connect error. Do I need any other equipment? Is the port correct? Do I need to config anything on the heater? My online connection is Genesis online is working.

image

nhogblom commented 1 year ago

You need to enable modbus TCP, you find this setting under installer settings/installatörs inställningar if i recall correctly. The pump has to be in OFF setting to show this menu.

Above atleast apply on my Thermia Calibra, i would assume it is the same for your model.

ehskha commented 1 year ago

Thanks, Thats what I did and now it connects.