Closed adamlewinter closed 9 years ago
To get this ball rolling, what's the ts code for the Gilbert Point laser system voltage?
I suggest displaying Laser profile and Laser voltage in a separate "box" above the rest of the values, and adding a "Gilbert Point" and "Haenke Island" title above each block of values.
By "values", do you mean this list of sensor names?
If that's the case, then you're picturing splitting that list into two parts with bold-ish headings above the parts, that say Gilbert Point and Haenke Island, e.g. roughly:
With vertical space between the lists?
@dcfinnegan has the ts code for the Gilbert voltage.
Yes to the "values" question and the bold titles.
Don't bother separating, just tag the voltage names.
Need to add a couple more TS codes for this site. Specifically, we need to separate the TS codes for battery voltage. Right now, we don't know which is which and there is only one on the site.
@dcfinnegan I'm having trouble connecting to gold1db from my local connection, any way that you could look up the battery TS codes that I need? One I have the codes I can update the site. Thanks.
Per Greg Hanlon:
Gilbert is: HUB.Volt-2.Inst.1Hour.0.DCP-raw Haenke is: HUB.Volt.Inst.15Minutes.0.DCP-raw
That's Gilbert @ 19072021 and Haenke @ 18683021, for those keeping score at home.
We need to include the voltage data from the Gilbert Point laser system, and differentiate between Gilbert Point vs. Haenke Island station data. I suggest displaying Laser profile and Laser voltage in a separate "box" above the rest of the values, and adding a "Gilbert Point" and "Haenke Island" title above each block of values.