Open CSaungsomboon-FTT opened 3 months ago
Theory: https://byjus.com/physics/thermal-stress/ https://amesweb.info/StructuralAnalysisBeams/Thermal-Stress-Plate.aspx https://www.roymech.co.uk/Useful_Tables/Mechanics/Plates.html https://fgg-web.fgg.uni-lj.si/~/pmoze/esdep/master/wg08/l0100.htm https://fgg-web.fgg.uni-lj.si/~/pmoze/esdep/master/wg08/l0200.htm https://fgg-web.fgg.uni-lj.si/~/pmoze/esdep/master/wg08/l0300.htm
Solutions: https://fgg-web.fgg.uni-lj.si/~/pmoze/esdep/master/wg08/l0300.htm https://www.wevolver.com/article/5-ways-to-strengthen-your-sheet-metal-parts
OSU standard: E906-21.pdf
Selected mechanical requirements:
Will change to 321 SS at 2mm thickness.
Will increase diameter of mounting holes from 7.5 to 9.5(?), Will retain diameter of 4x mounting holes for positioning
Issue to document the problems with the OSU backplate. Issue was raised with Isovolta in Austria in 20/07/2023 service visit.
https://www.fire-testing.com/rate-of-heat-release-apparatus/
11315-000-1