Swap panel dimensions in Analyzer #55

Closed ghost closed 5 years ago

ghost commented 6 years ago

This note: image has been thrown when testing the cutting list for the custom lockers for LNCO 10811/10776

I remember this, but I can't find where I've added it or any emails to/from Pythapartners. Sent email to them to try and work out what is causing this.

ghost commented 5 years ago

This was the response I got from Pytha Partners in September:

Katie Sayour 17 Sep 2018 10:33 AM ( responded in 4 days ) From "PYTHA Technical Services"support@pythapartners.com.au Hi Josh,

This error is because of the direction that Pen 20 has been applied in your PYTHA model, or because no Pen 20 was applied. Analyzer has very specific ideas about where Pen 20 should be - please see the list below. If your grain direction needs to be different, you have to rotate the parts in Analyzer after you're run the Geometry Scripts.

When exporting from PYTHA to Analyzer, it is important to ensure that your model has Pen 20 applied to all parts. This helps Analyzer to correctly orientate parts and ensure correct machining is applied. The following list details which edge should have Pen 20 applied, depending on Part Name.

Vertical:

End LH
End RH
Hinge Panel
Hinge Post
Division
DivisionRT
Back
Door LH
Door RH
DF
Fixed Panel

Horizontal:

Top
Bottom
CR Front
CR Back
Adj Shelf
Fixed Shelf
DBottom
DBack
DFront
DSide
Bench Top
ghost commented 5 years ago

Adding pen 20 to a vertical edge of the locker door causes this to work as expected. Need to go through the Locker Library and add the line 20 specification to it.

ghost commented 5 years ago

All of the 1500 high lockers except for the Z doors had 2 edges with pen 20 set. They worked fine. 1800 High lockers are the same.