Closed SergeBakharev closed 1 week ago
M220 just sets the program speed
You can only get it to go down to 50% override at the top.
But if you pause the program and use M220 You can get it down to 10% override if you want
Do "M220 S10" sets feedrste to 10%
more range for program speed
Increase the feed rate scaling range from 50-200 to 10-300. The stepping is still 10%
M220 just sets the program speed
You can only get it to go down to 50% override at the top.
But if you pause the program and use M220 You can get it down to 10% override if you want
Do "M220 S10" sets feedrste to 10%