Closed mjmarin closed 3 years ago
We have solved our doubt. Closing this issue.
Hi, the OpenGait is released now! ( https://github.com/ShiqiYu/OpenGait ) This project not only contains the full code of gaitpart but also reproduces several SOTA models of gait recognition. Enjoy it and any questions or suggestions are welcome!
Dear authors, first of all, congratulations on your great work. Reviewing your results on CASIA-B, using 50 subjects for testing (Section 4.1), we wonder what are the exact video sequences that are not included in the actual test. I mean, if per scenario and camera, 2 sequences are used per subject for testing, this makes a total of 100 sequences. Therefore, any number of correctly classified sequences reported as a percentage cannot have decimal numbers, e.g. Table 3, scenario CL #1-2, GaitPart(ours) --> 70.7 (if you correctly predict 70 out of 100 sequences, that's 70.0). Same with all remaining results in the table. Apologies in advance if this is a naive question and the answer is written somewhere else. Thank you very much.