ChrisVeigl / BrainBay

Open Source Biofeedback Software
http://brainbay.lo-res.org
Other
166 stars 52 forks source link

Muse 5th Electrode not recognized #37

Closed encoded-evolution closed 2 years ago

encoded-evolution commented 2 years ago

Hi @ChrisVeigl - I am using a 5th electrode with the Muse 2, but BrainBay does not recognize it. Using an alternate app, I can see that the electrode is producing signal - so the Muse and electrode are ok.

On the Brainflow website it appears that it should be supported. Is this something that I have to enable with a config string, or does this require an update to the code?

ChrisVeigl commented 2 years ago

yes - the config string can be sent to the device - maybe th 5th channel can be activated this way... but i never tried it because i have no device supportng this feature...

encoded-evolution commented 2 years ago

What is the syntax for that string? When I insert it and then apply config, the app crashes

Sent via the Samsung Galaxy S8 Active, an AT&T 5G Evolution capable smartphone Get Outlook for Androidhttps://aka.ms/ghei36


From: Chris Veigl @.> Sent: Saturday, September 17, 2022 5:46:56 PM To: ChrisVeigl/BrainBay @.> Cc: encoded-evolution @.>; Author @.> Subject: Re: [ChrisVeigl/BrainBay] Muse 5th Electrode not recognized (Issue #37)

yes - the config string can be sent to the device - maybe th 5th channel can be activated this way... but i never tried it because i have no device supportng this feature...

— Reply to this email directly, view it on GitHubhttps://github.com/ChrisVeigl/BrainBay/issues/37#issuecomment-1250145286, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AAL2YLSVH75YUSLYPA3PUGDV6Y35BANCNFSM6AAAAAAQPFC2JI. You are receiving this because you authored the thread.Message ID: @.***>

ChrisVeigl commented 2 years ago

hi,

I'm sorry i cant help here because i don't have access to the HW... I'd suggest to ask this question in the Brainflow forum or slack channel:

https://brainflow.readthedocs.io/en/stable/AskHelp.html https://openbraintalk.slack.com/

encoded-evolution commented 2 years ago

Here is the solution: in the config string field in the EEG Brainflow biosignal compatable settings, type

p50

that does the trick.

ChrisVeigl commented 2 years ago

nice! - thanks :)