Odd Power readings on one CT #51

Closed kgalilio closed 2 years ago

kgalilio commented 2 years ago

I've got one Main Board with two Addon boards stacked on top. All are working fine, with the exception of Addon 1 CT8 (middle left). The CT Clamp is clamped to monitor an Air Conditioner. With 18 Amps and 230V, I am expecting to see values around 4,000 Watts; however, I am getting very low values (fluctuating between 2W and 80W). If the Voltage, Frequency and Amps are correct and using the same power and calibration factors for all sensors, what causes this one to misread? I've changed 3 CT clamps already, and they all produce similar results.

image image

CircuitSetup commented 2 years ago

How is the CT reading the 2 phases of the 2 pole circuit? Something is likely backwards since a low power reading would indicate a low power factor.

kgalilio commented 2 years ago

Do you mean the clamp could be installed backwards? If that's the case, shouldn\t it cause the values to read negative?

CircuitSetup commented 2 years ago

Is the one CT around both wires? If so, they should be going in opposite directions through the CT.

kgalilio commented 2 years ago

I use single wire only. It's a 230V system, Common and Live. The clamp is around the Live wire.

On Sun, Aug 15, 2021, 19:37 John @.***> wrote:

Is the one CT around both wires? If so, they should be going in opposite directions through the CT.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/CircuitSetup/Expandable-6-Channel-ESP32-Energy-Meter/issues/51#issuecomment-899079059, or unsubscribe https://github.com/notifications/unsubscribe-auth/ALTDP45YHLKLF7ESFRC3NODT47UNTANCNFSM5CGJJNTQ . Triage notifications on the go with GitHub Mobile for iOS https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675 or Android https://play.google.com/store/apps/details?id=com.github.android&utm_campaign=notification-email .

CircuitSetup commented 2 years ago

Ohh, I see.

Okay, try turning the CT around on the wire.

kgalilio commented 2 years ago

Tried that. Similar fluctuating small values but negative!

On Sun, Aug 15, 2021, 21:20 John @.***> wrote:

Ohh, I see.

Okay, try turning the CT around on the wire.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/CircuitSetup/Expandable-6-Channel-ESP32-Energy-Meter/issues/51#issuecomment-899091548, or unsubscribe https://github.com/notifications/unsubscribe-auth/ALTDP4YDKHCVZ3CW7T2PF73T5AAODANCNFSM5CGJJNTQ . Triage notifications on the go with GitHub Mobile for iOS https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675 or Android https://play.google.com/store/apps/details?id=com.github.android&utm_campaign=notification-email .

CircuitSetup commented 2 years ago

If you switch the CT on the wire to a different channel on the meter then what happens?

wvoigt commented 2 years ago

I'm seeing something similar. But I have two wires, going through the sensor in opposite directions. Did anything every come of this after Aug 15?

miguelangel-nubla commented 2 years ago

I am also hitting this, even the same CT8. 230V Live/common. 233.1 V reading

energy-meter-main CT8 Amps  0.48 A  
energy-meter-main CT8 Watts 9.14 W  
CircuitSetup commented 2 years ago

I am also hitting this, even the same CT8. 230V Live/common. 233.1 V reading

energy-meter-main CT8 Amps    0.48 A  
energy-meter-main CT8 Watts   9.14 W  

This is possible if the power factor reading is low. Are you getting a reading for that?