Strange data shown by energy meter #14

Closed gurari closed 4 years ago

gurari commented 4 years ago

Hello, I've just connected my energy meter (CT1 only used for the moment) and connected it to my home network. When I scrolled down to the latest data column I'm seeing strange data:

Key Value
totV 1310.70
CT1 65.5350A
CT2 65.5350A
totI 131.0700A
W 0.0013W
PF 0.00
temp -1.00
freq 655.35

I've tried resetting the meter and factory reset but still the same.. Any clues what I'm doing wrong?

gurari commented 4 years ago

I assumed these values are some defaults when nothing is received from the software so I've opened the energy meter and found that nodemcu was not completely inserted into the socket. Maybe during the shipping something went wrong. Now all is ok when I pushed the nodemcu to the bottom.

CircuitSetup commented 4 years ago

I was going to suggest making sure it was seated. Glad you figured it out!