Open AnnettNFDI opened 3 years ago
The TLC image should be part of the analytics -> the ontology exists already and can be used, also image upload exists.
One should insert the TLC analysis with the reaction if the TLC is used as reaction control. If it's used as method to check the purity, then an assignment to the sample is suitable
Ok. Yes, I understand. That is logical. However, at the samples element there are no TLC fields to document solvent, rf-value etc, as available in the properties tab in reactions.
We created #572: it is almost finished. If you agree, I will close this issue?
Yes, it is fine to close the issue.
Video for tlc section in sample properties
Unfortunately, the video is not displayed. I get an error message, that the file is damaged.
are you sure? it works for me!
Seems to be a browser thing. Switching to chrome solved the problem. Sorry, my mistake ;). Now it works!
ok great
also updates on tlc section in reaction properties page. User can update tlc values from reaction property as well as sample property.
Thanks for the improvement! Just a few comments:
Hi Annett, Thanks for the thorough feedback.
Hi Adam, I talked to one of our active chemists about the TLC layouts. We agreed that the current draft is a bit unhandy. To us, it seems more useful to organise the documentation of TLC plate-wise. Therefore, we developed a draft for TLC documentation in samples and reactions. Of course, as you also mentioned the information should be connected (point 3 in you last comment). Our suggestion is to allow adding of a new TLC Control ( = a new TLC plate) and to have fields for eluent (solvent should be generally renamed to eluent. An eluent can contain a mixture of several solvents, which is often the case), for the sample/reactant/product and the respective Rf value and a field for TLC Description. As this should be the mandatory information for every TLC Control. If one does another TLC Control with another eluent than all the ifnormation should be entered again. The TLC descriptiopn field is important for all plates, as there are e.g. differnt plate types, methods for visualisation or dates, that should be recorded together with the values. If it is possible, we suggest to restrict tha valid values for Rf Value to 1.0, as this is always the eluent control and Rf Values for any sample must be smaller. As comment to your first point above: Ok, Now I understand. That was not clear for me from the video, but sounds absolutely reasonable ;).
As a user I wish to upload and display a TLC plate image directly in the properties tab in the reactions element as there are also documented the information on TLC plate conditions.
As a user I wish to upload and display a TLC plate image directly in the properties tab in the reactions element as there are also documented the information on TLC plate conditions.