Hey, Great project and the charging worked nearly out of the box but it just can't neater the Power with the S0 counter. It stays at 0.00kW the whole time. I checked the S0 pins and it drags 3.3V down to 0V every 0.5Wh and the pulse is supposed to be 80ms. Any Idea what could be wrong? Thx

twityde commented 5 years ago

Did you check the polarity? It is important how you connect the S0. S0+ to GND, S0- to D3/GPIO1.

fsg4u commented 5 years ago

Hey, Yes I did. Didn‘ work either but I just changed the GPIO and now it’s working. Perhaps it’s just that the GPIO is broken

Von: Thomas Williamson [mailto:notifications@github.com] Gesendet: Freitag, 24. Mai 2019 08:35 An: CurtRod/SimpleEVSE-WiFi Cc: fsg4u; Author Betreff: Re: [CurtRod/SimpleEVSE-WiFi] Metering just doesn't work (#27)

Did you check the polarity? It is important how you connect the S0. S0+ to GND, S0- to D3/GPIO1.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/CurtRod/SimpleEVSE-WiFi/issues/27?email_source=notifications&email_token=AMBQB67BBF6F4WHDFCL6X33PW6EB7A5CNFSM4HMIY4N2YY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGODWEJJZY#issuecomment-495490279 , or mute the thread https://github.com/notifications/unsubscribe-auth/AMBQB6Y7XXX6NSLWHR3W2CTPW6EB7ANCNFSM4HMIY4NQ . https://github.com/notifications/beacon/AMBQB6YLRPVLSDF7AFNST73PW6EB7A5CNFSM4HMIY4N2YY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGODWEJJZY.gif

hgmendes commented 5 years ago

I'm having this problem now. S0+ connected to D3 and S0- to GND, but stays at 0.00 kWh.

Meter doesn't inform impulse lenght, but I've tried with 80 and 60ms.

Anyone has this working with an Orno OR-WE-507 meter?

CurtRod commented 5 years ago

Did you try to change the polarity? Many other Orno electricity meters have a pulse length of 90ms. For the OR-WE-507 I could find no exact information. If necessary, ask the manufacturer directly.

hgmendes commented 5 years ago

Hi,

Thank you for your reply. I've already asked manufacturer but until now theres no answer :/

Regards,

Hugo Mendes GSM PT: +351 916 903 578 Skype: hgmendes

CurtRod notifications@github.com escreveu no dia sábado, 31/08/2019 à(s) 00:24:

Did you try to change the polarity? Many other Orno electricity meters have a pulse length of 90ms. For the OR-WE-507 I could find no exact information. If necessary, ask the manufacturer directly.

— You are receiving this because you commented. Reply to this email directly, view it on GitHub https://github.com/CurtRod/SimpleEVSE-WiFi/issues/27?email_source=notifications&email_token=ACEE42B6Z2IKW3JK6ANVLJ3QHGT35A5CNFSM4HMIY4N2YY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGOD5S7UYY#issuecomment-526776931, or mute the thread https://github.com/notifications/unsubscribe-auth/ACEE42CHE6AVWTSEZBXIKNLQHGT35ANCNFSM4HMIY4NQ .

hgmendes commented 5 years ago

Solved! Works ok with 90ms pulse! Thank you!