Item Interfaces not accepting "ticks per operation" other than 1 #245

Closed SirGeremiah closed 2 years ago

SirGeremiah commented 2 years ago

Issue type:


Short description:

On standard item interface (not filtering version), it won't accept a tick value higher than 1.

Steps to reproduce the problem:

  1. Add item interface on an inventory.
  2. Enter GUI and set ticks per operation to any number other than 1 (type or use iterating buttons - I tried multiple values up to 20).
  3. Click Save.
  4. Value reverts to 1.

Expected behaviour:

Entered value should be accepted.


Versions:

This has been replicated by met4000 in a clean test world, InDy 1.10.2, InTu 1.8.6.

Log file:

rubensworks commented 2 years ago

Thanks for reporting!

Jack-McKalling commented 2 years ago

I can also reproduce this. The GUI does save settings, as I can successfully change the side setting from east to down for instance, it's just the ticks setting specifically.