DCS-LCSR / SignStream3

Sign language linguistics annotation software
2 stars 0 forks source link

3.4.0 Failure to keep utterance names the same in temporal partition and segment tier: CN can reproduce #625

Open cneidle opened 1 year ago

cneidle commented 1 year ago

This should not be possible:

Screen Shot 2023-01-24 at 11 24 39 AM Screen Shot 2023-01-24 at 11 24 20 AM

I'm not sure how this happened. I intended to type WORK_AGENT for the first and WRITE_SENTENCE for the second...

gregorydimitriadis commented 1 year ago

Yes - I'm also not sure how that would have happened, as there is no isolated way to rename an utterance from the segment tier row.

cneidle commented 1 year ago

This may have been related to the fact that I had renumbered the utterances, prior to renaming them. I don't know.

cneidle commented 1 year ago

Here's one way to reproduce this. I click on the "U21" label and I accidentally get brought into the utterance window, but the text box persists. If I enter the text while in the utterance window and then go back to the database window, this is what I see:

Screen Shot 2023-02-02 at 4 09 24 PM
cneidle commented 1 year ago

The persistence of the Utterance label box in the utterance window, mentioned just above, was shown in another ticket:

Screen Shot 2023-02-02 at 4 14 28 PM

Here's another example:

Screen Shot 2023-02-02 at 4 26 22 PM
cneidle commented 1 year ago

Another scenario: I click on "U31". The textbox from the previous utterance is activated. I click on U31 again, and the previous utterance name appears in the segment tier label for U31.

Screen Shot 2023-02-02 at 4 18 18 PM Screen Shot 2023-02-02 at 4 18 28 PM Screen Shot 2023-02-02 at 4 18 36 PM
cneidle commented 1 year ago

Happened again. While ROBOT was selected, I clicked on the following Utterance name; exact same sequence of events as above.

Screen Shot 2023-02-02 at 4 21 58 PM Screen Shot 2023-02-02 at 4 22 31 PM
cneidle commented 1 year ago

Another sequence:

I click on SQUEEZE

Screen Shot 2023-02-02 at 4 29 21 PM

I click on U39

Screen Shot 2023-02-02 at 4 29 29 PM

I click on U39 again

Screen Shot 2023-02-02 at 4 29 38 PM

I click on U39 again

Screen Shot 2023-02-02 at 4 29 49 PM
cneidle commented 1 year ago

I opened RIT-SignBank-2a.ssc and found this! Obviously should not be possible:

Screen Shot 2023-02-02 at 9 44 01 PM
cneidle commented 1 year ago

When I tried to add an utterance to the temporal partition above, this happened:

Screen Shot 2023-02-02 at 9 46 22 PM
cneidle commented 1 year ago

I can delete the "U50" above, but I have no way to delete NORTH_WEST on the segment tier.

Screen Shot 2023-02-02 at 9 48 13 PM
cneidle commented 1 year ago

I should note that I accidentally labelled two utterances in a row with the same name. There are two occurrences of "NORTH+WEST" in a row. I meant to add an extra _ in the second one, but neglected to do so. I deleted the second one, but I still can't delete that first one...

Screen Shot 2023-02-02 at 9 50 41 PM
cneidle commented 1 year ago

I then saved the file with the second one deleted and re-opened it, and things appeared as they should.

Screen Shot 2023-02-02 at 9 52 53 PM
cneidle commented 1 year ago

related to #624