New geometry needs changes to reconstruction #166

Open AsaNehm opened 4 days ago

AsaNehm commented 4 days ago

With the new geometry of TMS switching over to 6 modules instead of 4 with then 32 scintillator bars each instead of 48, and in addition the scintillator thickness changing to 17mm instead of 10mm, there are some changes necessary in the reconstruction. Start of a list of issues and solutions (to be) implemented in a new branch for the future. !!!No merge onto main while still running on old geometry models!!!

AsaNehm commented 4 days ago

TMS_Constants.h

AsaNehm commented 4 days ago

TMS_TrueParticle.h

AsaNehm commented 4 days ago

TMS_Reco.cpp

AsaNehm commented 4 days ago

Made the necessary changes in TMS_Reco.cpp

AsaNehm commented 4 days ago

Adding in the changes in TMS_Constants.h that we already now

AsaNehm commented 1 day ago

Changed the number of thick and double steel plates after the decision in the engineering meeting last Friday. Still waiting for official notification of this