drift time window #219

Open YifanC opened 2 months ago

YifanC commented 2 months ago

The drift time window is provided as a standalone parameter in the detector configuration file. It is not associated / calculated from the drift distance or electric field, which makes it rather inflexible to change to other detector configuration and prong to errors. To be improved.