Closed dillasyx closed 7 years ago
put a blank biometric card in your security station. 32 channel limit is hard coded in the AE2 API. the AE2 devs would need to add in a function on their end for limitless network relaying. alternatively you can use P2P tunnels or disable AE2's channels entirely via the configs
i disabled channels completly, everything works now, thanks
I disabled channels and put a biometric card into the ME System, so every user has all rights, just to test everything. I recognized some strange things with the time. I changed the roundel RF/tick up to around 80kRF/t to be sure, energy isn't the issue. Then i built a system with autocrafting and so on. First "bug" when i build more than 2 quantum bridges the whole system crashes. When I send a crafting request the system crashes. So I wanted to find the bug and built everything without roundels. Just placed cables through the tardis and disconnected all roundels. The System uses around 1k-2k RF/t and works correctly with just cables. I don't know a possible reason, do you have an idea? Should i try latest jenkins build or wait for a new release? EDIT: newest jenkins build also doesn't work. 2+ quantum bridges are too much and more than one molecular assembler too
odd... ive not run into issues such as that and i was testing the ME system integration for dark while he was implementing the linking system. if you could do the following.
1)recreate a system that causes the problem so that it can fit in a single screen shot 2)provide the version number of AE2 and AE2 addons you are using with config settings
put that info here and i will look into it on my instance to try and track down the culprit
AE2 - rv2-stable-10 AE2 Stuff - 0.5.0.56-mc1.7.10 ExtraCells2 - 1.7.10-2.3.14b197
any system that is using more than 2k RF/t breaks
O.o im on rv3. dose the ME system die only when connected to the tardis or does it die when setup "normally" as well?
only on tardis
well im fighting a tps issue atm but once that calms down im going to (try to) bump up my ME systems power requirements
okay, all i find out is doesn't matter what is connected, the tardis me system just allows energy input of 2k RF/t, then system shuts down due to energy loss. I you're around 1.9k RF/t and store Stacks of items the terminal shuts down after every stack, then reboots. More energy acceptor have no effect to the system. Easy to test with the Wireless Transmitter and 64 range upgrades because it needs 8k RF/t and instantly shut down everything.
and i just vein mined my AE setup....
im having no issues
which version are you using? newest beta? and whats your rf/t?
rv_beta_5 over 8k. what ever the issue is thats causing your problem appears to either be AE2 stuff (incompatible with rv3 iirc) or an older bug that was fixed in later AE2 versions
ae2 stuff is such usefull, but if it works only without it, i have to remove it, I'm trying now
i know its useful but like i said, it may just be cos you are using an older version of AE2.
i tried with beta 6, but still same, the energy cell just gives 2k RF/t, now i try without aestuff
also, are you giving it enough rf/t? i assume you are but i never did ask
i use the creative energy cell so it should, i guess, wait i have a look, because it still dont work
the creative EC has a configured max output
and if it helps om feeding power straight into the MEcontroler
output is at 500k RF/t, should be enough and without channels there is no MEcontroller
have you tried adding ME energy cells (normal, not creative)
beyond that im stumped
wow, now it works, i always used the energy acceptor, but okay now i feel stupid
me controler work?
no controller ingame after channel deactivated, it's not needed but system works now thank you
ok. your issue was obviously the me energy acceptor does not have a big enough internal buffer for more than 2k rf
yeah but when i place a acceptor on the energy cell and then the creative cell there are around 2.3k Rf/t through the acceptor, it's weird
but anyway it works, thank you a lot for your time
np :P
care to close this issue @nidico100
I have to restart the world, that new ME Devices connect to ME System and on every restart I have to replace the core, that the system generally starts working via roundels Also when I directly place the ME Controller on more than one Roundel, only one will be used with 32 channels. And cables have to be replaced to connect to the roundel again Even if there isn't a direct connection and i connect 16 dense cables with different colors, only 32 channels will connect only through one cable, the other won't be used is it possbile for each roundel 32 channels or limitless, so only the cables make a limit? Even when channels are disabled in config, the tardis won't handle more than 2 quantum bridges and break the whole me system if more are connected.