V540TU: Option `Previous power state restoration` doesn't work #931

Open filipleple opened 2 months ago

filipleple commented 2 months ago

Component

Dasharo firmware

Device

NovaCustom V54 14th Gen

Dasharo version

v0.9.0-rc7

Dasharo Tools Suite version

No response

Brief summary

Previous power state restoration option doesn't boot the platform if it was powered on during power failure

How reproducible

100%

How to reproduce

Go to Power Management Options and set the Power state after power failure option to The state at the moment of failure. Then reset the platform to save the change, get it to boot and simulate a power failure.

Expected behavior

It should power the platform back on.

Actual behavior

It won't power back on when you plug the AC back in, no matter what state the platform was in upon failure.

Similar to the V560TU issue, however this time if you set the option to Powered On, it will be turning on the machine after cutting and restoring power. Only the previous state restoration doesn't boot it up.

Screenshots

No response

Additional context

No response

Solutions you've tried

No response

mkopec commented 2 months ago

The state The state at the moment of failure is not implemented yet, only Powered On is actually implemented

macpijan commented 2 months ago

The state The state at the moment of failure is not implemented yet, only Powered On is actually implemented

So we need to keep this issue open until it is. I think it is not a critical feature for @wessel-novacustom

wessel-novacustom commented 2 months ago

The state The state at the moment of failure is not implemented yet, only Powered On is actually implemented

So we need to keep this issue open until it is. I think it is not a critical feature for @wessel-novacustom

I confirm.

philipandag commented 3 weeks ago

Still happens on V560TNE v0.9.1-rc3