SDSSXCS-11154 had a real point source contamination problem #59

Closed DavidT3 closed 8 months ago

DavidT3 commented 2 years ago

This is basically fixed now, but I'm adding this as an additional record to what I put in the sample_properties notebook.

image

Those two sources were initially both covered by one XAPA region (one for each ObsID, of which there are two). I've gone in, changed the XAPA coordinate in the sample files, altered the XAPA regions (seen in green at the centre) so that they only cover the cluster, and then added a custom source to deal with the point source.

This is all in line with what Paul did for this cluster

DavidT3 commented 2 years ago

It's not perfect, but it is a damn sight better than what it was like initially, and hopefully the temperature/lum result will reflect that.

DavidT3 commented 2 years ago
image

This is what it actually ended up looking like, I had to redo it because I was stupid and didn't set my savepath