Dendrowen / Blobifier

GNU General Public License v3.0
194 stars 23 forks source link

Issues with probing. #33

Open Zchulski opened 3 weeks ago

Zchulski commented 3 weeks ago

The shaker arms is too big for the Voron tap, at least for mine. the X axis parts hit the shaker arm and throw off tap when probing the bed

Dendrowen commented 2 weeks ago

I had no issues with voron Tap on this, but changing the QGL locations more inward might help. I don't really have any other solution because the arm needs to be able to reach the toolhead.

Strangehadron commented 1 week ago

Hi, Just install a blobifier and I have the same issue with a tap (the printed one by voron team)

Hardware: Voron 2.4 300, with 305mm stock bed, (8mm M4 knurled nuts spacer for mounting bed), Voron tap (printed)

Problems :

Video when QGL: https://github.com/user-attachments/assets/bb80e926-940e-4f52-9515-64b499ab2653

Motor position (i had already cut a little part on the wall of the bucket on this picture): IMG_1766

A contributor of voron discord (fboc, thanks to him) looked the 2.4 and blobifier cad and said that with a spacer (M4 knurled nuts) for the bed less than 8.5mm the bottom screw (the bhcs one) of left xy joint is going to touch the shaker arm. https://discord.com/channels/460117602945990666/500407802414628876/1306742829636128778

It make sense with the tap since the toolhead go lower than other popular probing solution.