Closed GoogleCodeExporter closed 9 years ago
Original comment by bson...@gmail.com
on 20 Aug 2012 at 3:50
I'm not sure that power counting (current*voltige *time ?) is the best way to
manage battery, as the results depends of the discharge current, due to the
internal resistance of the battery.
On the contrary, capacity (current*time) couting is more efficient, as
discharged capacity of a battery is nearly independant of the current
(expecially for small currents). More, it is very easy to compare to a
reference value (that is the nominal capacity of the battery) and it is
applicable to all chimistry (please see below examples of discharge curves for
Sanyo Eneloop 2000 and Hyperion G3 CX).
Original comment by f.ague...@wanadoo.fr
on 27 Aug 2012 at 6:36
Attachments:
Original comment by bson...@gmail.com
on 3 Sep 2012 at 6:14
Original issue reported on code.google.com by
pbootsma
on 20 Aug 2012 at 2:15