DomiStyle / esphome-panasonic-ac

Open source alternative for Panasonic air condition wifi adapters that works locally without the Comfort Cloud
MIT License
221 stars 54 forks source link

Power consumption when 2 indoor units on one outdoor unit #86

Open HA-TB303 opened 1 year ago

HA-TB303 commented 1 year ago

Hi, I have 2 indoor units CS-TZ25WKE attached to 1 outdoor unit.

I use the ESP32 CN-CNT variant in both indoor units. I have 2 energy sensors reporting the same when idle (both 8 watt) and they also seem to be reporting the same when in use.

Is this energy consumption measurement taken from the outdoor unit for the whole system combined?

DomiStyle commented 1 year ago

The power consumption was not implemented by me but from what I remember it's just a rough approximation, which is probably why you get the same values.

I assume if one is idle and one is on you get different values?

HA-TB303 commented 1 year ago

Nope, the values are practically always identical. Sometimes one is a little faster reporting then the other, but generally they are the same.

DomiStyle commented 1 year ago

Interesting, could indeed be that the calculation is done on the outdoor unit instead.

Does the value double if one AC is on and you turn another one on a little bit later?

HA-TB303 commented 1 year ago

No, it stays the same.

DomiStyle commented 1 year ago

Strange, that makes it even more useless than it was with a single unit.

War3333 commented 1 year ago

I have the official intesys knx adapter for my knx system, i can confirm that the consumption is indeed calculated on the outdoor unit and will be reported to be the same on both units. The consumption of the inside split are few watts anyway (tested with a real amperometric sensor) so i don't think it really matters.

nicx commented 9 months ago

I have 3 indoor units with the same behaviour. Is it confirmed that this is by design? In the cloud app I cann see slightly different power values between the 3 indoor units. Is Panasonic itself also using the outdoor unit for estimating power consumption?

qwert4712 commented 2 months ago

"For Multi-Split AC Systems, the energy consumption value displayed is for whole system."

see https://www.panasonic.com/global/hvac/products/comfort-cloud/how-to-use-comfort-cloud/check-air-conditioner-energy-consumption.html