Open Robert-Riedl opened 2 months ago
i've disabled my workaround to capture the logoutput:
2024-04-12 15:15:23 - __main__[ DEBUG] - Reading sensor data for device schlafzimmer
2024-04-12 15:15:23 - libs.waveplus[WARNING] - Failed to communicate with device schlafzimmer (attempt 1 of 4): Helper not started (did you call connect()?)
2024-04-12 15:15:24 - libs.waveplus[WARNING] - Failed to communicate with device schlafzimmer (attempt 2 of 4): Helper not started (did you call connect()?)
2024-04-12 15:15:25 - libs.waveplus[WARNING] - Failed to communicate with device schlafzimmer (attempt 3 of 4): Helper not started (did you call connect()?)
2024-04-12 15:15:25 - libs.waveplus[WARNING] - Failed to communicate with device schlafzimmer (attempt 4 of 4): Helper not started (did you call connect()?)
2024-04-12 15:15:25 - __main__[ ERROR] - Failed to communicate with device schlafzimmer: Failed to communicate with device 2930223305/schlafzimmer
I have now currently 3 devices that are being read with the Bridge and have run in a strange issue - sometimes some devices stop responding (not always the same one, though some more often than others).
But its immediately fixed with restarting the waveplus bridge python script.
so for now, I just have a cronjob that restarts it hourly...
I realize this is difficult to diagnose, with all the variables of different hardware, range and bluetooth in general... maybe you have some idea though ?