alpha_isc #12

Closed toddkarin closed 4 years ago

toddkarin commented 4 years ago

@cwhanse Technically, alpha_isc depends on temperature. Should we use alpha_isc_ref for alpha_isc at reference conditions and alpha_isc at any temperature?

cwhanse commented 4 years ago

That is my view, although I'd say "alpha_isc at any condition" there can be a spectral dependence as well.

toddkarin commented 4 years ago

We have decided to just use alpha_isc (i.e. no _ref) as it is typically assumed this value is at reference conditions.