ENGYS / HELYX-OS

The market leading open-source GUI for OpenFOAM®
Other
114 stars 38 forks source link

wrong pressure unit indication #2

Closed saladinheart closed 8 years ago

saladinheart commented 8 years ago

On Helyx OS v2.3.1 while setting up a VOF model, boundary conditions and Fields initialisation for the pressure should be given in Pa and not in m2/s2 as indicated in the gui.

saladinheart commented 8 years ago

Is is not a bug, so I close the issue, ambiguity comes form the fact that P_rgh is in Pa while P is in m2/s2.

HELYX-OS commented 8 years ago

Ok!