ESCOMP / CAM-SIMA

Community Atmosphere Model - System for Integrated Modeling of the Atmosphere
4 stars 12 forks source link

Call to physics_types_tstep_init out of place #165

Closed gold2718 closed 2 years ago

gold2718 commented 2 years ago

The call to physics_types_tstep_init sets the tendencies to zero but if we are reading snapshot data, we need to do that after that to feed the correct tendencies to the suite. This was not an issue for the simpler suites because the tendencies were already zero.