Control of DWH heating element #478

Open Skol6 opened 2 months ago

Skol6 commented 2 months ago

Hi Folks,

In case I have a lot of energy delivered from my PV system, I want to activately switch on the external electric DHW heater. Do you know how this is possible with MQTT commands?

Regards!

IgorYbema commented 2 months ago

No that is impossible. However there are other options:

kgiedrius commented 2 months ago

but it is possible to turn on/off DWH and ROOM heaters from controll panel. Why it is not possible with integration ?

MiG-41 commented 2 months ago

No , it is not possible to switch them , it is possible only to deactivate them ( so they are not turning on during heating - generally) , but you can't just turn on/off them , for this it is HP with decides . ( there is a possibility to turn on manually ,but this is service menu , HP have to be switched off ).

MiG-41 commented 2 months ago

I use for that porpuse Shelly1PM . This turns on/off DHW heater , and at the same time to contact it is connected HP , so when HP want's to turn on heater , shelly do it as well.

IgorYbema commented 2 months ago

Even if you do a 'force dhw heat' on the controller panel (or using heishamon command) this will not exactly do what you want (only use the heater element) and will not always start immediatly. Using the trick as @MiG-41 described is a good solution and fits my 2nd option in my post above.