En3rGy / 14105_go-eCharger

Gira KNX Homeserver logic module to interact with an go-eCharger.
MIT License
1 stars 1 forks source link

dws has wrong scaling #8

Closed En3rGy closed 1 year ago

En3rGy commented 1 year ago

Reported in https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/1582969-neuer-baustein-14105_go-echarger?p=1891532#post1891532

Scaling of value is done by 1/10 what might be wrong

En3rGy commented 1 year ago

Following: https://github.com/goecharger/go-eCharger-API-v1/blob/master/go-eCharger%20API%20v1%20DE.md

Geladene Energiemenge in Deka-Watt-Sekunden Beispiel: 100'000 bedeutet, 1'000'000 Ws (= 277Wh = 0.277kWh) wurden in diesem Ladevorgang geladen.

Therefore, the scale shall be 1 * 10 / 1000 = 1 / 100