Equipment-and-Tool-Institute / j1939-84

J1939-84 implementation for etools.org
MIT License
7 stars 6 forks source link

SP 588 Length needs to be updated in section 6.1.9.3.a #1193

Closed anthonyhbest closed 1 month ago

anthonyhbest commented 1 year ago

Per closed issue #967 please update section 6.1.9.3.a to match the appendix. Issue #967 resolution: image image

Appendix A has been updated in the latest draft proposal, but section 6.1.9.3 wording was not updated to match. The following WARN seen in 3.1.6 release should be an INFO:

image

ericthomasswenson commented 1 year ago

I’ll change eight to six

6.1.9.3 Warn Criteria for OBD ECUs a. Warn if the serial number field (SP 588) from any function 0 device is less than six characters long.

ericthomasswenson commented 1 year ago

This was a error of omission … Appendix A-1 says <html xmlns:o="urn:schemas-microsoft-com:office:office" xmlns:w="urn:schemas-microsoft-com:office:word" xmlns:m="http://schemas.microsoft.com/office/2004/12/omml" xmlns="http://www.w3.org/TR/REC-html40">

aa b A12345  –  ending delimiter missing Pass [6 character, 5 numeric digit serial number example]