Incorrect implementation of A.5.3.C when checking Active 100-Hour arrays. #1220

Closed anthonyhbest closed 1 month ago

anthonyhbest commented 1 year ago

It appears the tool is checking the values in the active 100-hour arrays immediately before issuing a DM11. The tool then issues failures for some active 100-hour arrays that are greater than 0, which would make sense but only if the check is executed after the DM11. Part 9: image

Part 12: image

Latest Task 5 Document: image

anthonyhbest commented 1 year ago

Here is the request/response for SPN 12700 and 12707 from part 9: image

Here is the request/response for part 12: image