Required Data Stream SPNs are not supported. SPNs: 12744 … Reported for CI engine. #1234

Closed ericthomasswenson closed 1 month ago

ericthomasswenson commented 1 year ago

Required Data Stream SPNs are not supported. SPNs: 12744

was observed on a CI engine. But, EVAP is SI only.

Please correct SP 12744, Evap. System Purge Pressure, to SI only.

Observed on 3.1.14.

naroner commented 1 year ago

I'm still seeing this is 3.1.19:

Required Data Stream SPNs are not supported. SPNs: 166 Required Data Stream SPNs are not supported. SPNs: 12748 Required Data Stream SPNs are not supported. SPNs: 3516, 3518, 7346 FAIL: 6.1.4.2.b - N.2 One or more SPNs for data stream is not supported Required Data Stream SPNs are not supported. SPNs: 132 Required Data Stream SPNs are not supported. SPNs: 166 Required Data Stream SPNs are not supported. SPNs: 245, 917 Required Data Stream SPNs are not supported. SPNs: 4360 Required Data Stream SPNs are not supported. SPNs: 12744 Required Data Stream SPNs are not supported. SPNs: 12750 Required Data Stream SPNs are not supported. SPNs: 12751 Required Data Stream SPNs are not supported. SPNs: 12752 Required Data Stream SPNs are not supported. SPNs: 12753 Required Data Stream SPNs are not supported. SPNs: 3516, 3518, 7346 WARN: 6.1.4.3.a - SPN not supported in DM24 Required Data Stream SPNs are not supported. SPNs: 74 Required Data Stream SPNs are not supported. SPNs: 101 INFO: 6.1.4.3.a - SPN not supported in DM24 More than one of the SPNs are reported as supported. SPNs: 110, 1637, 4076, 4193 INFO: 6.1.4.3.b - More than 1 SPN supported

battjt commented 1 year ago

The logic for 6.1.4.2.b is separate from the rest of the A1 table. It was broken in multiple places.