EspoTek / Labrador

EspoTek Labrador is a USB device that transforms your PC or smartphone into a fully-featured electronics lab. This repo holds all of the source code!
http://espotek.com
1.1k stars 116 forks source link

Single shot trigger not working on windows 10 #217

Closed drmolix closed 2 years ago

drmolix commented 2 years ago

The single shot trigger does not work for any channel. I start with a constant 5V reading. When I set the triggering value to 3V level on falling edge and check the "single shot" box, the readings become frozen. Sending 0V to the monitored channel doesn't do anything.

image

EspoTek commented 2 years ago

In the screenshot, it's looking for a rising edge. Everything you've described is expected behaviour in this case.

It won't be able to require any rising edge at all from a 5V-0V transition.

drmolix commented 2 years ago

Hi, thanks for replying so fast. Actually I tried both ways, falling edge - 5v initial and rising edge - 0v initial, without any good response from the single shot triggering. In the screenshot I sent you I just had the scope set for the rising edge and forgot to switch it back but it wouldn't have changed anything. I can record a full video if you want.