When I use the web page to run a simulation of a 50 nm gold ball at 6 keV I get 0 photons. If I change the material to water I get 5000 photons. Something is fishy...
This should have been only an issue for the WWW version. There was a hardcoded massdensity for gold in the wrong unit (g/cm3 instead of kg/m3). Should be fixed now.
When I use the web page to run a simulation of a 50 nm gold ball at 6 keV I get 0 photons. If I change the material to water I get 5000 photons. Something is fishy...