FaritaTasnim / comm

1 stars 1 forks source link

coupling strength limit? #1

Closed DemenzEchtbaer closed 1 year ago

DemenzEchtbaer commented 1 year ago

Hi Farita,

Thank you for your inspiring article, and thank you for providing your code! No real issue here, rather a simple question: in the energy switching scenario, can the couplings of the reservoirs be greater than 1? I accidentally input very large values for the two reservoirs in your code (35 for both) and got some oscillating behavior in the evolution of the ctmc, see attached pic. noisy_channel_ctmc

Cheers,

FaritaTasnim commented 1 year ago

Hi there,

Yes feel free to set the couplings to any value you choose - however, do note that the assumptions of stochastic thermodynamics hold only in the overdamped limit. So it's possible that the results you get for the EP, etc., in scenarios where the coupling drives the system into the underdamped limit might not be accurate. Thanks for the question!

DemenzEchtbaer commented 1 year ago

Hey there,

Indeed, I hadn't thougt of this, thank you so much for your insights! Looking forward to your next articles :-)

Cheers,