FrSkyRC / ETHOS-Feedback-Community

Feedback & suggestions are welcomed here for ETHOS by FrSky
188 stars 85 forks source link

Voltage sensor limits too low #3444

Closed rburrow87 closed 7 months ago

rburrow87 commented 7 months ago

Ethos 1.4.17. Have not checked 1.5.0-RC3 yet.

The maximum voltage for ISRM sensor ID 0A 0B50 is only 50.00v, which causes problems with a fully charged 12S LiHV setup (and sometimes even full charged 12S LiPo).

Same issue with the CRSF/ELRS Rx Batt voltage sensor (ID 08 in my models), except it is limited to 50.4v.

These limits should be at least 61 volts to accommodate up to 14S LiHv. Probably slightly higher for sensors that are not calibrated perfectly. I see some other voltage sensor IDs have 65v and 100v as limits.

bsongis-frsky commented 7 months ago

RBOX did already allow 65.0V Now RBOX and ESC will share the same constant = 65.0V Ready for 1.5.0 RC5