"XML: The returned XML does not match the expected schema. (code: PE233) -- JSON: The returned JSON does not match the expected structure (invalid JSON). (code:PE231)" #1

Open Chrigon-hub opened 3 years ago

Chrigon-hub commented 3 years ago

Hi,

I am getting the "XML: The returned XML does not match the expected schema. (code: PE233) -- JSON: The returned JSON does not match the expected structure (invalid JSON). (code:PE231)" error when using this script. Any ideas on how to resolve this? I am using PRTG Network Monitor 20.4.64.1402

Thanks,

Fredde87 commented 3 years ago

Hey, does your configuration parameters contain any unusual characters?

Do you have enough PowerShell knowledge the run the script in PowerShell and see what data it returns?

Also what iDirect modem and version do you have? This script is very outdated now as iDirect have completely changed their command structure. I haven't worked with a iDirect modem for years but I am actually working on a new project at the start of next year where I will have access to one so if I get some spare time I will try to update this script

Chrigon-hub commented 3 years ago

Hey,

Thanks for your response. I don't have much powershell knowledge sorry. Just go through guides and stuff to try get things working. iDirect X7.


From: Fredde87 notifications@github.com Sent: Saturday, 26 December 2020 8:44 AM To: Fredde87/PRTG-iDirect-sensor PRTG-iDirect-sensor@noreply.github.com Cc: Chrigon-hub christiaan.kuhn@hotmail.com; Author author@noreply.github.com Subject: Re: [Fredde87/PRTG-iDirect-sensor] "XML: The returned XML does not match the expected schema. (code: PE233) -- JSON: The returned JSON does not match the expected structure (invalid JSON). (code:PE231)" (#1)

Hey, does your configuration parameters contain any unusual characters?

Do you have enough PowerShell knowledge the run the script in PowerShell and see what data it returns?

Also what iDirect modem and version do you have? This script is very outdated now as iDirect have completely changed their command structure. I haven't worked with a iDirect modem for years but I am actually working on a new project at the start of next year where I will have access to one so if I get some spare time I will try to update this script

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHubhttps://github.com/Fredde87/PRTG-iDirect-sensor/issues/1#issuecomment-751293323, or unsubscribehttps://github.com/notifications/unsubscribe-auth/ASHUYQHB6YPDDEA6B4RS4XLSWUBU7ANCNFSM4VGIEEVA.

MuhammadHamzaChughtai commented 3 weeks ago

I'm using idirect X1 modem.. Although everything is added and configure as per instruction still EXL sensor is down.