Open rocco8773 opened 11 months ago
There does appear to be just enough room for the fitting to fit. There would be about a .37" gap between the collar and the fitting, and about a .44" gap between the fitting and TOF panel. Obviously a fitted foam piece will need to be made to protect the fitting from the TOF panel and visa-versa.
While there is enough vertical space for the fitting, there is NOT enough space between neighboring OHPs. If a fitting in placed in an area congested with OHPs, then that fitting will push against neighboring OHPs. (see pic below)
Answer archived into the code base...
docs/questions/Can a 90deg OHP connector fit at the top of the TKR.md
If an OHP is damaged inside the Tracker such that the straight section needs replacing, then a 90deg Swagelok #SS-3M0-9 fitting needs to be used to join the new section to the bent section above Layer 0 of the Tracker. So, is there enough room between the Layer 0 cooling collar and the top of the Tracker (bottom of TOF) for Swagelok fitting to fit?