Since the nut-plates or connecting plates that joining neighboring detector modules are designed to break when being removed, we should fabricate spare units for re-assembly of the Tracker. There are two types of connecting plats...
GAPS-TKR-MEC-206 Connection plate 1
4 hole design that connects 4 detector modules together
These are used in the interior of a layer
25 per layer, 250 units for the whole Tracker
Material: Al-6061-T6
Anodization: MIL-A-8625F, TYPE III, CLASS 1, THICKNESS 0.002"
Color: black
GAPS-TKR-MEC-207 Connection plate 2
2 hole design that connects adjacent detector modules
These are used at the exterior (edges) of a layer
20 units per layer, 200 units for the whole Tracker
Material: Al-6061-T6
Anodization: MIL-A-8625F, TYPE III, CLASS 1, THICKNESS 0.002"
Color: black
Question:
How many replacement units do we need of each variation?
Since the nut-plates or connecting plates that joining neighboring detector modules are designed to break when being removed, we should fabricate spare units for re-assembly of the Tracker. There are two types of connecting plats...
GAPS-TKR-MEC-206 Connection plate 1
GAPS-TKR-MEC-207 Connection plate 2
Question: