Closed ladsmund closed 2 months ago
The following figure shows the raw and processed surface downwelling longwave radiation for UWN.
rad_t
. rad_t
on February 9th and started transmitting erroneous values in April. Looks good!
I added t_rad to the variable list
Note that in L1toL2 dsr
and usr
values for which t_rad
values are invalid are removed:
https://github.com/GEUS-Glaciology-and-Climate/pypromice/blob/af09818bd0bc98b51b90bb680eb840e74502aa3a/src/pypromice/process/L1toL2.py#L85-L86
So since it is an issue of t_rad
, it would be sufficient to flag only t_rad
.
There is an issue with the radiometer thermometer causing it stop transmitting or to transmit erroneous data.