Vessel Name

Tribiah_Lee

Issue Type

other_not_listed

Date Observed

2021-12-20

Symptom

logger timeout while waiting for STP 8686782910914088812

Potential Fix

@xhx509 suggests charging probe

GMaynard1 commented 2 years ago

Erin says she charged the probe last night, will try again

ErinGOMLF commented 2 years ago

I am sending the probe that isn't working (the logger timeout issue) back to Huanxin to pass along to Nick. I have a replacement probe for Tribiah_Lee that I will give to Dan on a visit to Gloucester.

ErinGOMLF commented 2 years ago
ErinGOMLF commented 2 years ago

[ ] Erin changed the mac address on the pi, but the bluetooth got turned off, Emma has turned it back on and we will wait to see if he gets a plot next time he hauls

ErinGOMLF commented 2 years ago

Dan isn't fishing the gear that has the probe on it, he will let Erin know when he is putting that back in the water.

Jack-ODN commented 2 years ago

I have a new system all ready to go, just waiting to for opportunity to visit Nicole Leigh and I will install system on Dans boat

GMaynard1 commented 2 years ago

Sweet, so he's back to groundfishing now?

Jack-ODN commented 2 years ago

Visited on Friday (11/4) - He just put his boat back in the water, trawl doors were not on the boat. I pulled the old system off. He is likely going to start trawling again by the end of this week (11/7). Hopefully will catch him later in the week and install moana on trawl door.

Jack-ODN commented 2 years ago

Swung by on 11/9 while I was in Gloucester, still no doors on board. I got his deckhand Rob's phone number too, hopefully will get system back on there soon.

Jack-ODN commented 1 year ago

Installed moana sensor on trawl door yesterday (12/1). System is tested and ready to go, data should start flowing.