Open NoahJst opened 4 months ago
Warning 2024-06-25 19:40:34Polling Error: meterSerialNumber,siteId Error: ZCL command 0x587cdeeffa34v7/1 seMetering.read(["meterSerialNumber","siteId"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed ({"target":1770,"apsFrame":{"profileId":260,"clusterId":1794,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":98},"zclSequence":151,"commandIdentifier":1} timed out after 10000ms)
Warning 2024-06-25 19:41:12Polling Error: averageRmsVoltageMeasPeriod,activePowerMax,activePower Error: ZCL command 0x587cdeeffa34v7/1 haElectricalMeasurement.read(["averageRmsVoltageMeasPeriod","activePowerMax","activePower"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":2820,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":110})
Warning 2024-06-25 19:41:17Polling Error: activePowerPhB Error: ZCL command 0x587cdeeffa34v7/1 haElectricalMeasurement.read(["activePowerPhB"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":2820,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":111})
Warning 2024-06-25 19:41:27Polling Error: ticMode,elecMode,contractType Error: ZCL command 0x587cdeeffa34v7/1 manuSpecificGmmts.read(["ticMode","elecMode","contractType"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed ({"target":1770,"apsFrame":{"profileId":260,"clusterId":65346,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":114},"zclSequence":159,"commandIdentifier":1} timed out after 10000ms)
Warning 2024-06-25 19:41:32Polling Error: uptime,refreshRate,maxContractPower Error: ZCL command 0x587cdeeffa34v7/1 manuSpecificGmmts.read(["uptime","refreshRate","maxContractPower"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":65346,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":117})
Warning 2024-06-25 19:41:42Polling Error: motdetat,powerMaxTodayTime,powerMaxYesterday Error: ZCL command 0x587cdeeffa34v7/1
Firmware version V3.2.7
HA MQTT see
Hello,
I have the same issue with the V3.2.9 I give you my log from the reset, pass by linking to Z2M and data retrieve.
esp-web-tools-logs-test-zigbee.txt
Here I put Z2M logs :
[2024-07-06 23:37:39] warning: TICMeter: Polling Error: averageRmsVoltageMeasPeriod,activePowerMax,activePower Error: ZCL command 0x404ccafffe53b308/1 haElectricalMeasurement.read(["averageRmsVoltageMeasPeriod","activePowerMax","activePower"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 61792 - 1 - 128 - 2820 - 1 after 10000ms)
[2024-07-06 23:38:03] warning: TICMeter: Polling Error: activePowerPhB Error: ZCL command 0x404ccafffe53b308/1 haElectricalMeasurement.read(["activePowerPhB"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 61792 - 1 - 129 - 2820 - 1 after 10000ms)
[2024-07-06 23:38:27] warning: TICMeter: Polling Error: ticMode,elecMode,contractType Error: ZCL command 0x404ccafffe53b308/1 manuSpecificGmmts.read(["ticMode","elecMode","contractType"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 61792 - 1 - 130 - 65346 - 1 after 10000ms)
[2024-07-06 23:38:50] warning: TICMeter: Polling Error: uptime,refreshRate,maxContractPower Error: ZCL command 0x404ccafffe53b308/1 manuSpecificGmmts.read(["uptime","refreshRate","maxContractPower"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 61792 - 1 - 131 - 65346 - 1 after 10000ms)
I can send other logs if needed.
Now, I will wait the next version like I see on Discord to renew my test and see if updates resolve this issue.
Hello,
similar issue here (not exactly the same log message) with V3.2.9
Z2M Journal logs :
[2024-07-17 07:41:03] warning: TICMeter: Polling Error: meterSerialNumber Error: ZCL command 0x404ccxxxxxxxxxxx/1 seMetering.read(["meterSerialNumber"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (SRSP - AF - dataRequest after 6000ms)
[2024-07-17 07:42:39] warning: TICMeter: Polling Error: rmsCurrentMax Error: ZCL command 0x404ccxxxxxxxxxxx/1 haElectricalMeasurement.read(["rmsCurrentMax"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (SRSP - AF - dataRequest after 6000ms)
[2024-07-17 07:42:45] warning: TICMeter: Polling Error: ticMode,elecMode,contractType Error: ZCL command 0x404ccxxxxxxxxxxx/1 manuSpecificGmmts.read(["ticMode","elecMode","contractType"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (SRSP - AF - dataRequest after 6000ms)
[2024-07-17 07:42:51] warning: TICMeter: Polling Error: uptime,refreshRate,maxContractPower Error: ZCL command 0x404ccxxxxxxxxxxx/1 manuSpecificGmmts.read(["uptime","refreshRate","maxContractPower"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (SRSP - AF - dataRequest after 6000ms)
[2024-07-17 07:42:57] warning: TICMeter: Polling Error: motdetat Error: ZCL command 0x404ccxxxxxxxxxxx/1 manuSpecificGmmts.read(["motdetat"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (SRSP - AF - dataRequest after 6000ms)
What is annoying is that it seems to overload the serial link between my Zigbee Coordinator and HA machine and make it crash after a while, so all my others Zigbee peripherals are not accessible too
The problem encountered
TICMeter sous Zigbee avec Z2M
CAS 1 :
Polling Error: meterSerialNumber Error: ZCL command 0x404ccafffxxxxxxxxx/1 seMetering.read(["meterSerialNumber"] Received network/route error ROUTE_ERROR_NON_TREE_LINK_FAILURE for "61635".
CAS 2 :
Polling Error: meterSerialNumber,siteId Error: ZCL command 0x404ccafffe46838c/1 seMetering.read(["meterSerialNumber","siteId"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 31878 - 1 - 133 - 1794 - 1 after 10000ms)
Firmware version
V3.2.7
Steps for reproducing the error
No response
What I've already tested
No response
Relevant log output
No response