Open clairebio27 opened 3 years ago
Hello @clairebio27, quite a complex setup you got there.
I'm not sure I understood everything, but I would use the link between the HTO and the barcodes to decipher which TCR comes from which cells, then use this as annotation for your TCR analysis.
Regarding the HTO, do you have one per fastqs? Or do you have 9 starting cell types mixed across all the 9 HTO fastqs?
Hi Patrick,
Thank you for the email.
I have cell types mixed across all (mostly more than one HTO) HTO fastqs.
I have used a naive approach to analyse this data.
So in short, I haven't used cell rager count or CITE seq or Seurat for the analysis.
Could these results be wrong? What could be the difference in results if I do the analysis this way and HTOdemux using Seurat? Am I going the wrong direction?
Claire
On Sat, Aug 1, 2020 at 7:08 AM Patrick Roelli notifications@github.com wrote:
Hello @clairebio27 https://github.com/clairebio27, quite a complex setup you got there.
I'm not sure I understood everything, but I would use the link between the HTO and the barcodes to decipher which TCR comes from which cells, then use this as annotation for your TCR analysis.
Regarding the HTO, do you have one per fastqs? Or do you have 9 starting cell types mixed across all the 9 HTO fastqs?
— You are receiving this because you were mentioned. Reply to this email directly, view it on GitHub https://github.com/Hoohm/CITE-seq-Count/issues/128#issuecomment-667514506, or unsubscribe https://github.com/notifications/unsubscribe-auth/AQNV4PZ7KDQQ66B2ERMSNHLR6PZRFANCNFSM4PKLUBEA .
Hello @clairebio27, I'm sorry but I'm having a hard time following your main question. The design of the experiment is not clear to me and I would not want to tell you something wrong.
In 1, I notice you have not retrieved the UMI. This means you won't have any deduplication information. SO your data will be "biased" by potential different duplication rates.
If the design is right, what you miss out by doing everything yourself is cell barcode correction, umi correction, mapping errors that are both being done in cell ranger and CSC.
Our objective is to test TCR Ab Oligos to define starting cell type, and also to Test the ability to pool samples with TCR Ab Oligos.
We are using 10X for single cell analysis and illumina for sequencing. We have used 9 different HTOs and have 9 samples .
This is something I am trying for the first time and therefore I am reaching out to see a workflow for the analysis to meet the objectives. I have 9 fastqs (R1,R2 and I for each sample) for ADT(HTOs),9 fastqs for TCR from illumina , What I have done so far is: