IEAWindTask37 / IEA-15-240-RWT

15MW reference wind turbine repository developed in conjunction with IEA Wind
Apache License 2.0
215 stars 138 forks source link

Why have I replaced the latest DISCON.IN, or is there an error #162

Closed Bq2181 closed 4 months ago

Bq2181 commented 1 year ago

Running AeroDyn. Running InflowWind. Running HydroDyn. WARNING: The requested output channel is invalid: WavesF1xi WARNING: The requested output channel is invalid: WavesF1zi WARNING: The requested output channel is invalid: WavesM1yi WARNING: The requested output channel is invalid: WavesF2xi WARNING: The requested output channel is invalid: WavesF2zi WARNING: The requested output channel is invalid: WavesM2yi WARNING: The requested output channel is invalid: WavesF2xi WARNING: The requested output channel is invalid: WavesF2yi WARNING: The requested output channel is invalid: WavesF2zi WARNING: The requested output channel is invalid: WavesM2xi WARNING: The requested output channel is invalid: WavesM2yi WARNING: The requested output channel is invalid: WavesM2zi Generating incident wave kinematics and current time history. Calculating second order difference frequency wave kinematics. Calculating second order sum frequency wave kinematics. Reading in WAMIT output with root name ".\HydroData/IEA-15-240-RWT-UMaineSemi". Computing radiation impulse response functions and wave diffraction forces. Calculating second order difference-frequency force using the full quadratic transfer function. Running MoorDyn (v2.0.0, 2022-12-08). This is MoorDyn v2, with significant input file changes from v1. Copyright: (C) 2022 National Renewable Energy Laboratory, (C) 2019 Matt Hall Parsing MoorDyn input file: .\IEA-15-240-RWT-UMaineSemi_MoorDyn.dat Warning: invalid output specifier FX. Must start with L, C, R, or B Warning: invalid output specifier FY. Must start with L, C, R, or B Warning: invalid output specifier FZ. Must start with L, C, R, or B Created mooring system: 3 lines, 6 points, 0 rods, 0 bodies. Finalizing initial conditions using dynamic relaxation. t=60 FairTen 1: 2.43287E+06, 2.44526E+06, 2.43537E+06 Fairlead tensions did not converge within TMaxIC=60 seconds. MoorDyn initialization completed. Running ServoDyn. Running ServoDyn Interface for Bladed Controllers (using Intel Visual Fortran for Windows). Using legacy Bladed DLL interface.

FAST_InitializeAll:HydroDyn_Init:HydroDynInput_ProcessInitData: A requested output channel is invalid

At line 58 of file D:\bld\rosco_1615353392809\work\src\ReadSetParameters.f90 (unit = 89, file = '.\IEA-15-240-RWT-UMaineSemi_DISCON.IN') Fortran runtime error: Bad integer for item 1 in list input

D:\app\OpenFast\IEA-15-240-RWT-master\OpenFAST\IEA-15-240-RWT-UMaineSemi>

dzalkind commented 1 year ago

Hi, please try the latest version of ROSCO and this DISCON input on the develop branch.