Improve NacYIner calculation and fix error PtfmYIner missing value #99

Closed gbarter closed 2 years ago

gbarter commented 2 years ago

Purpose

A bug in the WEIS code for fixed-bottom led to zero-entry for PtfmYIner in the ElastoDyn file. In fixing this value, it was recommended to use just a placeholder (e.g. dummy) value and include 1/3 of the tower yaw inertia in the NacYIner value.

Type of change

Testing

gbarter commented 2 years ago

Matching WEIS PR