Closed thomruhl closed 1 year ago
Dear @thomruhl,
could you please send us the metadata to check the encoding? Thanks
Hi @fabiovinci,
Here is the metadata in attachment.
Best, Thomas
Dear @thomruhl,
thank you for the metadata.
The check you are referring to "should" be in the Conformance Class 4 (the "Data Quality" section of "Conformance Class 3" refers to another metadata element) but it is only a "Recommendation" (see section 4.2.2.1. Conformity of the MD TG) and they are not implemented.
I hope that this helps to clarify.
Hello,
There seems to be an issue with the "Data Quality" section of "Conformance Class 3" results of the validator when checking a network service metadata.
In our DQ_ConformanceResults, a wrong reference to Commission Regulation 1089/2010 instead of 976/2009 doesn't get flagged by the validator like we would expect it to be.
In attachment, you'll find the report.
Best regards, Thomas Ruhl
Test run on 1113 - 21.12.2022 with test suite Conformance Class 4 INSPIRE Network Services metadata.pdf