JeffersonLab / hallc_replay

Replay directory for Hall C hcana
0 stars 59 forks source link

Correct HMS and SHMS calibrations for CERN ROOT 6.30.04 on el9 #548

Closed mrcmor100 closed 4 months ago

mrcmor100 commented 4 months ago

Old calibrations from the Fortran analyzer have been archived. All old drift chamber calibrations have been removed. They have not been used in years and confuse newcomers.
HMS calibrations have been checked for completeness. SHMS calibrations have been checked if they compile.
SHMS NGC and CAL were updated recently and work well.

TODO: Update set_reftime and set_timing_windows to point to the same database parameters used in each relevant script. TODO: Add run_many_ped since the main reason to re-run the default pedestal is to look at runs before / after a shift and add back in events where the pedestal could not be calculated. This is a very small contribution of events. TODO: Check SHMS calibrations and add more accurate README for each calibration. TODO: Make all calibration scripts expect path to ROOTfile is the complete path. Mismatch between scripts leads to many hours troubleshooting for new users.