Modified CDC_amp plugin & script to use hits in first 100ns only in h… #1113

Closed nsjarvis closed 6 years ago

nsjarvis commented 6 years ago

…istograms for gain calibration

(so that hits at later drift time are ignored. These have lower gain, probably due to oxygen infiltration, due to the small leak in the chamber.)

nsjarvis commented 6 years ago

(also I deleted some code which isn't needed for the gain calibrations)

gluex commented 6 years ago

Test status for this pull request: SUCCESS

Summary: /work/halld/pull_request_test/sim-recon^nsj_CDC_amp_add_100ns_histos/tests/summary.txt Logs: /work/halld/pull_request_test/sim-recon^nsj_CDC_amp_add_100ns_histos/tests/log

Build log: /work/halld/pull_request_test/sim-recon^nsj_CDC_amp_add_100ns_histos/make_nsj_CDC_amp_add_100ns_histos.log Build report: /work/halld/pull_request_test/sim-recon^nsj_CDC_amp_add_100ns_histos/report_nsj_CDC_amp_add_100ns_histos.txt Location of build: /work/halld/pull_request_test/sim-recon^nsj_CDC_amp_add_100ns_histos