Closed GoogleCodeExporter closed 8 years ago
Can you please upload the pvhistory.s3db database file
I expect I will need to provide a diagnostic version to identify the cause.
Dennis M-F
Original comment by DennisMackayFisher
on 30 Aug 2011 at 12:11
Dennis I have attached the database file
Original comment by shaneo3...@gmail.com
on 31 Aug 2011 at 8:11
As you noted, your inverter is reporting EnergyTotal but not EnergyToday.
When present, EnergyToday has higher precision that EnergyTotal. I chose to use
EnergyToday as it allows calculation of energy output at 5 minute resolution.
EnergyToday only shows a change at each 0.1kwh change. It can take a long time
to see this change in low light conditions. This will produce a poor graph at
pvoutput unless some interpolation ia added.
pvoutput does not produce a continuous timeline. Discontinuities in the
timeline cause the timeline to be shortened. I will need to find a way to
generate the missing values by interpolation.
Dennis M-F
Original comment by DennisMackayFisher
on 3 Sep 2011 at 11:55
Try 1.7.0.0
It should produce a step graph upload. (if pvoutput accepts the high power
levels at the step points). I will look at adding interpolation soon.
Dennis M-F
Original comment by DennisMackayFisher
on 4 Sep 2011 at 1:49
When you try 1.7.0.2
Check Trace, Meter Trace and Meter Message on the Log Files tab, Save settings
This will produce a large log file in a short time.
Upload the PVService.log file and the settings.xml file
Dennis M-F
Original comment by DennisMackayFisher
on 7 Sep 2011 at 1:20
Dennis
tried 1.7.0.2 with no luck, still no inverter data to pvoutput. have attached
files as requested
Shane
Original comment by shaneo3...@gmail.com
on 8 Sep 2011 at 9:20
The log file above was not created with the trace setting I requested turned
on. When these settings are made the log files are very large with detail of
the messages passing to and from the devices you are using.
Please:
Check (tick) Trace, Meter Trace and Meter Message on the Log Files tab
Save settings
After about 20 minutes, upload the resultant log file.
Dennis M-F
Original comment by DennisMackayFisher
on 8 Sep 2011 at 8:57
Sorry Dennis the checkboxes had grey ticks in them and i thought this meant
they were selected.
Original comment by shaneo3...@gmail.com
on 9 Sep 2011 at 4:34
Please try version 1.7.0.4
Dennis M-F
Original comment by DennisMackayFisher
on 10 Sep 2011 at 6:43
Well 1.7.0.4 didn't work but at least I can see the fault. 1.7.0.5 seems to do
the right thing using my CMS Emulator.
Dennis M-F
Original comment by DennisMackayFisher
on 11 Sep 2011 at 1:08
Hi dennis
1.7.0.4 has worked and has uploaded inverter data to pvoutput :) I see you have another update so will put that on tonight and see how it goes.
Original comment by shaneo3...@gmail.com
on 11 Sep 2011 at 7:43
This is now very old - Is all well with the Orion?
Dennius M-F
Original comment by DennisMackayFisher
on 19 Feb 2012 at 8:26
Yes thanks Dennis, all is ok. Thanks once again for a terrific program. :)
Original comment by shaneo3...@gmail.com
on 22 Feb 2012 at 8:04
Original comment by DennisMackayFisher
on 24 Feb 2012 at 9:30
Original issue reported on code.google.com by
shaneo3...@gmail.com
on 30 Aug 2011 at 7:05