Generated does not match Inverter #90

Closed GoogleCodeExporter closed 8 years ago

GoogleCodeExporter commented 8 years ago
What steps will reproduce the problem?
1. Deleted pvoutput 23/07+ restarted PVBC with force Live Upload.
2. Deleted pvoutput 04/08 restarted PVBC with force Live Upload.
3.

What is the expected output? What do you see instead?
Inverter says 22.194 and 43.446 uploaded to PVoutput

What version of the product are you using (e.g. 1.4.1.9 32bit)?
PVBC 1.5.0.5 - 32 bit

What Operating system (XP, Vista, Windows 7 - 32bit or 64bit)?
XP SP Pro 2002 SP3 - 32 bit

Which Database Type (MySQL, MS Access, SQLite - If Access, 32bit or 64bit)?
SQLite

Are there any unusual messages in PVService.log? (upload a copy to this
issue if there are)

Please upload your settings.xml file with the issue. This answers many
questions I would otherwise need to ask.

Please provide any additional information below.

All inverter data auto upload from the 24/07 onwards. Generated output does not 
match from 24/07 onwards which has been uploaded by PVBC.

Original issue reported on code.google.com by k...@gardiner.com.au on 5 Aug 2011 at 5:57

GoogleCodeExporter commented 8 years ago
You have two inverter managers enabled, both Sunny Explorer and the Current 
Cost meter. If these are both reading yield from the same inverter, you should 
disable the Current Cost inverter manager. Your current config is probably 
loading the same yield from two different data sources. 

The Sunny Explorer inverter manager is the most accurate and should be used in 
preference to Current Cost where possible.

Dennis M-F

Original comment by DennisMackayFisher on 6 Aug 2011 at 12:24

GoogleCodeExporter commented 8 years ago
Dennis,
Yes, thanks. I see what I have done. I have now have selected the Sunny 
Explorer inverter manager only. Today's yield from the inverter is 23.580 and 
pvoutput says 23.560. This is now good!

As I understand, to correct past days I should:
Delete Live and Daily from pvoutput and check PVBC to "Force Live Upload" and 
set number for the number of "Live Upload Days" required. Save 
Settings>Stop>Start PVBC service and when PVBC has finished it work writing to 
SQLite db stop the service and change teh "pvoutput.org Settings" back to 
normal and wait for the data to be accepted at pvoutput.org.

I am now watching to see what gets uploaded to pvoutput.org. I will check 
tomorrow and see how the figures compare with the inverter. The 03/08 should be 
12.186 according to the inverter, but uploaded already showing 23.293 with 
still more to upload.

Once PVBC writes to the SQLite db (as in my case) does PVBC re-write data to 
the SQLite db correctly?

Oh bother! Just noticed that 43.446 has been uploaded again for 04/08 and it 
should be 22.194. Now I'm not sure how to correct the data, thought I was on 
the right track.

Kim

Original comment by k...@gardiner.com.au on 6 Aug 2011 at 1:20

GoogleCodeExporter commented 8 years ago
Dennis,
Deleted all incorrect dily and live data at pvoutput. Uploaded manually. All 
working from 07/08/11 onwards. Please close issue.
Thanks, Kim

Original comment by k...@gardiner.com.au on 13 Aug 2011 at 5:57

GoogleCodeExporter commented 8 years ago

Original comment by DennisMackayFisher on 14 Aug 2011 at 3:17