DECSYSTEM 2020 RH11 - RM03/RP06 - RELIABILITY DIAGNOSTIC Failure #17

Open jfcl opened 6 years ago

jfcl commented 6 years ago
* SMMON [DSQDC] - DECSYSTEM 2020 DIAGNOSTIC MONITOR - VER 0.3 *

SMMON CMD - DSRMB

DSRMB - DECSYSTEM 2020 RH11 - RM03/RP06 - RELIABILITY DIAGNOSTIC
VERSION 0.2, SV=0.3, CPU#=4097, MCV=130, MCO=470, HO=0, KASW=003740 000000

TTY SWITCH CONTROL ? - 0,S OR Y  - Y

LH SWITCHES <# OR ?> - 10
RH SWITCHES <# OR ?> - 20000
SWITCHES = 000010 020000

MEMORY MAP =
FROM     TO          SIZE/K
00000000 03777777       1024

RH11 - 1 - MASSBUS CONFIGURATION
DRIVE - STATUS OF UNIT FOUND

0 - RP06, DRIVE SER. NO.=0011., (OFFLINE)
1 - RP06, DRIVE SER. NO.=0012., (OFFLINE)
2 - RP06, DRIVE SER. NO.=0013., (ONLINE), WRT PROTECTED
*** 11 FORMATTED BY, DRIVE SER. NO.=0000.,
NAME    ID      TYPE

3 - RP06, DRIVE SER. NO.=0014., (OFFLINE)
4 - RP06, DRIVE SER. NO.=0015., (OFFLINE)
5 - RP06, DRIVE SER. NO.=0016., (OFFLINE)
6 - RP06, DRIVE SER. NO.=0017., (ONLINE), WRT ENABLED
*** 10 FORMATTED BY, DRIVE SER. NO.=0000.,
NAME    ID      TYPE

7 - RP06, DRIVE SER. NO.=0018., (ONLINE), WRT ENABLED
*** 10 FORMATTED BY, DRIVE SER. NO.=0000.,
NAME    ID      TYPE

WHAT DRIVE(S) TO BE TESTED (00 TO 77, ALL, H=HELP)? - ???
TYPE H FOR HELP
DRIVE(S)? # - 7

TYPE "H" FOR TEST NAME HELP MESSAGE
WHAT TEST ? - FORMAT

FORMAT A PACK? Y OR N  - Y

CYLINDER 000 SURFACE 00 CAN NOT HAVE ANY "HARD" ERRORS!

36 BIT MODE (10 FORMAT)? Y OR N  - Y

VERIFY AFTER FORMATTING? Y OR N  - Y

PROCESS ENTIRE PACK FOR ALL SELECTED DRIVES? Y OR N  - Y

PROGRAM RUN TIME = 0:0:18       FORMATTING STARTED
KS10: Halted.
KS10: Halt Cause: Illegal Interrupt Instruction. (PC=051611)
  Halt Status Block Address is 376000
  PC  is 000000051611     HR  is 702300000100
  MAG is 377777777777     ONE is 000000000001
  AR  is 000000000100     ARX is 000000000001
  BR  is 000000376000     BRX is 000000000000
  EBR is 000020000000     UBR is 500000000000
  MSK is 777777777777     FLG is 034000000000
  PI  is 000000002377     X1  is 000001000001
  TO  is 000000000000     T1  is 000000000002
  VMA is 140000051611
KS10>
jfcl commented 6 years ago

This is a problem with the RH11 Interrupt Controller. The DSRPA Diagnostic passes all of its tests, but does not exercise the interrupt controller, apparently.