[x] Period is missed at the end of section1 paragraph.
[x] The first paragraph in section3 has three "?" which means the referencing is missed.
[x] The section 3 paragraph is associated to SWHS, you must customize it for your program, it seems some part of it is remained from the template.
[x] It's better to change "the following table" to the table 1 in section4.
[x] In section 5.2, "Optimization (Section ??), Energy (Section??), are not address correctly.
[x] It's better to consider that "All required sections of the template are present for all modules".
[x] In 5.4.2, Access Routine Semantics: the exception part should be added for main function.
[x] It seems that "#Power distribution Li = Ri + Pi" is a part of your code, is it right?
[x] In section 6, you wrote "The secrets of this module are the data structure for input parameters," but I think the secret of the input module is the input data not the data structure.
[x] Some sections and subsection are deleted, for example "exported access programs" in 6.3.
[x] What is "... ... ..." in section 6.3?
[x] "readtable(filename)" in section 6.4.3 is load_params? it should be corrected.
[x] In section 6.4.4., load params(s) has no detailes.
[x] In page 7, the exceptions has no title, in addition, as I understood your constraints are not right, consider the "~" at the first of all expressions, you can delete the "~" or write your real constraint.
Some suggestions are prepared, hope to be useful.